2015 Environmental, Social and Governance Report

Year: 2015
Published: 2016-07-06
Status: Processed

Extracted ESG KPIs

KPIs are organized by ESG aspects.

The types of emissions and respective emissions data.

Indicator Unit 2014 2015 Report Pages
Discharged gas radioactive waste (inert gases) as a percentage of the national standards - Daya Bay % 0.133 21
Discharged gas radioactive waste (inert gases) as a percentage of the national standards - Daya Bay Base % 0.133 0.133 32
Discharged gas radioactive waste (inert gases) as a percentage of the national standards - Hongyanhe % 0.144 21
Discharged gas radioactive waste (inert gases) as a percentage of the national standards - Hongyanhe Nuclear Power Station % 0.176 0.144 32
Discharged gas radioactive waste (inert gases) as a percentage of the national standards - Ningde % 0.15 21
Discharged gas radioactive waste (inert gases) as a percentage of the national standards - Ningde Nuclear Power Station % 0.15 0.53 32
Discharged gas radioactive waste (inert gases) as a percentage of the national standards - Yangjiang % 0.18 21
Discharged gas radioactive waste (inert gases) as a percentage of the national standards - Yangjiang Nuclear Power Station % 0.127 0.18 32
Discharged liquid radioactive waste (radionuclides other than tritium) as a percentage of the national standards - Daya Bay % 0.21 21
Discharged liquid radioactive waste (radionuclides other than tritium) as a percentage of the national standards - Daya Bay Base % 0.162 0.219 32
Discharged liquid radioactive waste (radionuclides other than tritium) as a percentage of the national standards - Hongyanhe % 0.47 21
Discharged liquid radioactive waste (radionuclides other than tritium) as a percentage of the national standards - Hongyanhe Nuclear Power Station % 0.84 0.47 32
Discharged liquid radioactive waste (radionuclides other than tritium) as a percentage of the national standards - Ningde % 0.24 21
Discharged liquid radioactive waste (radionuclides other than tritium) as a percentage of the national standards - Ningde Nuclear Power Station % 0.55 0.24 32
Discharged liquid radioactive waste (radionuclides other than tritium) as a percentage of the national standards - Yangjiang % 0.5 21
Discharged liquid radioactive waste (radionuclides other than tritium) as a percentage of the national standards - Yangjiang Nuclear Power Station % 0.068 0.059 32
Number of outages outages 10 13
Results of environmental monitoring - Daya Bay Base Normal Normal 32
Results of environmental monitoring - Hongyanhe Nuclear Power Station Normal Normal 32
Results of environmental monitoring - Ningde Nuclear Power Station Normal Normal 32
Results of environmental monitoring - Yangjiang Nuclear Power Station Normal Normal 32
Total duration of refueling outages days 480 13

Direct (Scope 1) and energy indirect (Scope 2) greenhouse gas emissions (in tonnes) and, where appropriate, intensity (e.g. per unit of production volume, per facility).

Indicator Unit 2015 Report Pages
Hongyanhe Unit 2 capability factor % 65.53 13
On-grid power generation equivalent to carbon dioxide emission reduction million tonnes 69.7 6

Total hazardous waste produced (in tonnes) and, where appropriate, intensity (e.g. per unit of production volume, per facility).

Indicator Unit 2014 2015 Report Pages
Solid radioactive waste - Daya Bay 317.6 21
Solid radioactive waste - Daya Bay Base 367.2 317.6 32
Solid radioactive waste - Hongyanhe 183.1 21
Solid radioactive waste - Hongyanhe Nuclear Power Station 12.58 183.1 32
Solid radioactive waste - Ningde 149.6 21
Solid radioactive waste - Ningde Nuclear Power Station 100 149.6 32
Solid radioactive waste - Yangjiang 2.44 21
Solid radioactive waste - Yangjiang Nuclear Power Station 24.4 32

Description of emissions target(s) set and steps taken to achieve them.

Indicator Unit 2014 2015 Report Pages
Nuclear power corresponding to carbon dioxide emission reduction ‘0000 tons 5796 6970 32
Nuclear power corresponding to sulfur dioxide emission reduction ‘0000 tons 56 67 32

Direct and/or indirect energy consumption by type (e.g. electricity, gas or oil) in total (kWh in '000s) and intensity (e.g. per unit of production volume, per facility).

Indicator Unit 2014 2015 Report Pages
Average capability factor % 88.14 13
Daya Bay Unit 1 capability factor % 78.83 13
Daya Bay Unit 2 capability factor % 86.8 13
Equivalent effect of nuclear power to reduce standard coal consumption ‘0000 tons 2356 2630 32
Installed capacity in operation MW 14918 6
Ling Ao Unit 1 capability factor % 93.64 13
Ling Ao Unit 2 capability factor % 90.1 13
Lingdong Unit 1 capability factor % 90.29 13
Lingdong Unit 2 capability factor % 79.74 13
Ningde Unit 1 capability factor % 93.21 13
Ningde Unit 2 capability factor % 78.95 13
Ningde Unit 3 capability factor % 87.75 13
On-grid power generation GWh 73401.6 88346.944 6, 32
Yangjiang Unit 1 capability factor % 99.64 13
Yangjiang Unit 2 capability factor % 87.16 13

Description of energy use efficiency target(s) set and steps taken to achieve them.

Indicator Unit 2015 Report Pages
Hongyanhe Unit 1 capability factor % 100 13

Description of the significant impacts of activities on the environment and natural resources and the actions taken to manage them.

Indicator Unit 2014 2015 Report Pages
Nuclear power generating units in operation unit 11 14 32
Nuclear power plants in operation MW 11624 14918 32
Number of overlapping outages overlapping outages 4 13

Description of the significant climate-related issues which have impacted, and those which may impact, the issuer, and the actions taken to manage them.

Indicator Unit 2015 Report Pages
Number of field trips to Daya Bay Nuclear Power Base or Yangjiang Nuclear Power Base trips 11 7

Total workforce by gender, employment type (for example, full- or part-time), age group and geographical region.

Indicator Unit 2014 2015 Report Pages
Administrative staff (function mix) % 7.76 28
Age 28 and below (age mix) % 42.2 28
Age 29 to 35 (age mix) % 34.48 28
Age 36 to 45 (age mix) % 15.55 28
Age 46 and above (age mix) % 7.79 28
College and below (diploma mix) % 12.84 28
Doctor (diploma mix) % 0.98 28
Female employees (sex mix) % 8.67 28
Female manager ratio (above level) % 17.19 28
Male employees (sex mix) % 91.33 28
Master (diploma mix) % 14.35 28
New employees number 1324 1014 32
Newly recruited employees people 1014 28
Operating revenue RMB billion 23.26 6
Percentage of female employees 8.64% 8.67% 32
Technical staff (function mix) % 92.24 28
Total assets RMB billion, RMB'000 220888499 217801358 6, 32
Total employees number 9717 11787 32
Total number of employees people, person 9717 11787 28, 32
Total number of employees (including those of affiliates) 11787 6
Undergraduate (diploma mix) % 70.83 28

Employee turnover rate by gender, age group and geographical region.

Indicator Unit 2015 Report Pages
Employee turnover rate % 2.04 28

Number and rate of work-related fatalities occurred in each of the past three years including the reporting year.

Indicator Unit 2014 2015 Report Pages
Death person 2 32
External operation accident (level 0) 11 9 32
Serious injury person 2 32

Description of occupational health and safety measures adopted, and how they are implemented and monitored.

Indicator Unit 2015 Report Pages
Number of first prizes in EDF safety challenge first prizes 32 13
Number of regular safety inspections by National Nuclear Safety Administration inspections 25 13

The average training hours completed per employee by gender and employee category.

Indicator Unit 2014 2015 Report Pages
Training time per capita hour 113 122 32
Training time per employee hour 113 122 32

Number of suppliers by geographical region.

Indicator Unit 2014 2015 Report Pages
Registered shareholders of H shares Shareholder 4213 4210 7

Number of products and service related complaints received and how they are dealt with.

Indicator Unit 2015 Report Pages
Number of persons participated in investor visits persons 270 7
Total working tickets working tickets 100000 13

Description of practices relating to observing and protecting intellectual property rights.

Indicator Unit 2011 2012 2013 2014 2015 Total Report Pages
Authorship Registration - Others 12 1 44 17 15
Authorship Registration - Software 46 59 45 32 73 255 15
Patent Application - Design 1 1 2 15
Patent Application - Invention 68 88 127 174 167 624 15
Patent Application - Utility Model 56 76 124 129 117 502 15
Patent Licensing - Design 1 1 2 15
Patent Licensing - Invention 24 48 35 33 47 187 15
Patent Licensing - Utility Model 49 59 95 168 133 504 15

Description of quality assurance process and recall procedures.

Indicator Unit 2014 2015 Report Pages
Percentage of advanced value achieved for WANO indicators of mature units 62.6% 65.3% 32
WANO mature units % 65.3 13
WANO new units % 71.9 13

Number of concluded legal cases regarding corrupt practices brought against the issuer or its employees during the reporting period and the outcomes of the cases.

Indicator Unit 2014 2015 Report Pages
Total tax payment RMB'000 1228041 1116185 32

Description of preventive measures and whistle-blowing procedures, and how they are implemented and monitored.

Indicator Unit 2014 2015 Report Pages
Effectiveness of communication with community and general public people, visits per annum Approximately 65000 people visited nuclear power bases 9
Effectiveness of communication with customer Carried out training activities with power grid enterprises 9
Effectiveness of communication with employee hours Organized over 300 seminars for young employees involving over 7500 people in the communication 9
Effectiveness of communication with environmental organization million tonnes On-grid electricity was equivalent to reduction of emission of approximately 69.7 million tonnes of carbon dioxide 9
Effectiveness of communication with government RMB million Underwent 25 on-site safety inspections by the National Nuclear Safety Administration 9
Effectiveness of communication with media Organized six press conferences 9
Effectiveness of communication with partner Conducting training for contractors 9
Effectiveness of communication with shareholder Conveyed one general meeting 9
Number of important resolutions considered and approved during the year resolutions 30 7
Number of special committee meetings held meetings 9 7
Total number of registered shareholders Shareholder 6741 6738 7

Description of anti-corruption training provided to directors and staff.

Indicator Unit 2015 Report Pages
Number of board meetings held meetings 5 7

Focus areas of contribution (e.g. education, environmental concerns, labour needs, health, culture, sport).

Indicator Unit 2014 2015 Report Pages
Number of investors visits organized visits 61 7
Number of persons participated in field trips to Daya Bay Nuclear Power Base or Yangjiang Nuclear Power Base persons 127 7
Visitor coverage of nuclear power base and exhibition hall 250000 6
Visitors admitted to nuclear power popularization of science exhibit hall '0000 visits 20 25 32
Visitors received in nuclear science exhibition halls in one thousand visits 20 25 32

Resources contributed (e.g. money or time) to the focus area.

Indicator Unit 2014 2015 Report Pages
Cumulative time for public service participated by employees hours 34900 6
Education surcharge payment RMB one hundred million 1 1 32
Volunteer service times Approximately 15000 Approximately 10000 32

Direct (Scope 1) and energy indirect (Scope 2) greenhouse gas emissions (in tonnes) and, where appropriate, intensity (e.g. per unit of production volume, per facility).

Standard Indicator Unit 2015
GHG Removals from Newly Planted Trees million tonnes 69.7

Total hazardous waste produced (in tonnes) and, where appropriate, intensity (e.g. per unit of production volume, per facility).

Standard Indicator Unit 2014 2015
Total Hazardous Waste 479.78 674.7

Description of emissions target(s) set and steps taken to achieve them.

Standard Indicator Unit 2014 2015
CO2 Emissions Reduction Compared to Last Year tons 57960000 69700000
SO2 Emissions Reduction Compared to Last Year tons 560000 670000

Direct and/or indirect energy consumption by type (e.g. electricity, gas or oil) in total (kWh in '000s) and intensity (e.g. per unit of production volume, per facility).

Standard Indicator Unit 2014 2015
Sold Electricity GWh 73401.6 88346.94

Total workforce by gender, employment type (for example, full- or part-time), age group and geographical region.

Standard Indicator Unit 2014 2015
Number of New Employees person 1014
Number of Total Employees person 9717 11787
Percentage of Bachelor's Degree Employees % 70.83
Percentage of Below Junior College Employees % 12.84
Percentage of Doctoral Degree Employees % 0.98
Percentage of Employees Aged 30-50 % 34.48
Percentage of Employees Aged Above 50 % 7.79
Percentage of Employees Aged Below 30 % 42.2
Percentage of Female Employees % 8.64 8.67
Percentage of Male Employees % 91.33
Percentage of Master's Degree Employees % 14.35

Employee turnover rate by gender, age group and geographical region.

Standard Indicator Unit 2015
Turnover Rate of Total Employees % 2.04

Number and rate of work-related fatalities occurred in each of the past three years including the reporting year.

Standard Indicator Unit 2014
Number of Fatalities as a Result of Work-related Injuries person 2
Number of Work-related Fatalities person 2

The average training hours completed per employee by gender and employee category.

Standard Indicator Unit 2014 2015
Average Training Hours per Employee hour 113 122

Description of practices relating to observing and protecting intellectual property rights.

Standard Indicator Unit 2011 2012 2013 2014 2015
Number of Intellectual Property Rights Obtained by the Company 131 168 177 277 253
Number of Patents Applied 125 165 251 303 284

Resources contributed (e.g. money or time) to the focus area.

Standard Indicator Unit 2014 2015
Number of Participations in Volunteer Activities times 15000 10000
Total Volunteer Service Hours hours 34900